1

11 Elements in 11 Seconds SampleSense FAST UHT Thermo Scientific™ iCAP™ 6000/7000 Series ICP-OES - SampleSense FAST
SampleSense FAST UHT uses an inert injection valve with built-in optical sensors that automatically detect the liquid sample, inject the valve and trigger the ICP read in a tightly-timed analytical sequence. SampleSense FAST UHT eliminates wasted time from the ICP method and can double or even triple sample throughput while recording missing or empty tubes.
<232> Elemental Impurities–Limits - prepFAST USP
This general chapter specifies limits for the amounts of elemental impurities in drug products. Elemental impurities include catalysts and environmental contaminants that may be present in drug substances, excipients, or drug products.
<233> Elemental Impurities–Procedures - prepFAST USP
This chapter describes two analytical procedures (Procedures 1 and 2) for the evaluation of the levels of the elemental impurities. The chapter also describes criteria for acceptable alternative procedures.
FAST DIAS: Dual Inlet Aerosol Switching MC-ICPMS - FAST DIAS
A Dual Inlet Aerosol Switching (DIAS) system is used to alternate between sample and standard aerosol streams. The balanced DIAS system practically eliminates uptake and washout time, greatly improving the frequency of sample standard bracketing for mass bias correction.
FAST with SampleSense - Urine Metals Analysis NexION 2000 ICPMS - SampleSense FAST
SampleSense FAST is the most recent advancement in FAST technology. SampleSense couples an autosampler with an inert valve having integrated optical sensors to automatically detect the presence of a non-segmented liquid sample.
AGU San Francisco 2016 Poster Note Recent Developments in MC-ICP-MS for Uranium Isotopic Determination from Small Samples - apex Omega
Here we evaluate the combination of Elemental Scientific apex Ω desolvation system and microFAST MC dual looploading flow-injection system with the Thermo Scientific NEPTUNE Plus MC-ICP-MS. The inlet systems allow for the efficient handling of small sample volumes with efficient desolvation to minimize the hydride interference on 236U.
Application Handbook for prepFAST S5 - prepFAST S5
The prepFAST S5 high purity automation system allows semiconductor labs to analyze these sensitive samples easily, without fear of contamination from the environment or from handling of the sample. The prepFAST S5 is capable of providing sub-ppt detection limits for critical semiconductor elements, as well as providing accurate calibration and quality control spikes at single digit ppt levels.
Application Note – PPQ Levels of Th in High Purity Cu TRUFAST ICPMS - TRUFAST
The TRUFAST utilizes a PFA column packed with TEVA Resin to concentrate Th from a solution of Cu dissolved in HNO3, allowing for accurate measurement at low ppq levels.
Automated Inline Dilution System for PerkinElmer Optima - prep3 DX
prep3 is an inline dilution system, which uses a peristaltic pump to perform precise and accurate inline dilution of samples and standards. Three microperistaltic pumps under the control of the Optima Syngistix software deliver sample, diluent, and internal standard to an inline, low-volume mixing device and then into the nebulizer. The total liquid flow is constant, but the ratio of sample to diluent varies to perform the inline dilutions.
Automated Inline Dilution System for PerkinElmer Optima - FAST for prep3
FAST for prep3 enhances laboratory productivity by adding FAST uptake, washout, and high throughput capabilities to the prep3 autodilution system. Syngistix control of a 7 port valve and three independent microperistaltic pumps is used to perform accurate and precise inline autodilution. Rapid mixing of samples or standards with diluent and internal standard in a fluoropolymer sample flow path provides minimal memory effects.
Automating metals analysis in blood samples - prepFAST M5c
The prepFAST M5c can eliminate the sample preparation step in the laboratory by allowing the analyst to put the undiluted blood directly onto the autosampler for analysis. This eliminates the time needed for sample preparation and bench or hood space normally required to prepare the samples.
Elemental Analysis of Wines from Various Regions Around the World - prepFAST IC - prepFAST IC
This work will present an automated method for measuring total elemental content and elemental speciation (arsenic and chromium) in wine using a single sample introduction platform (prepFAST IC) in combination with an ICP-MS. The total elemental measurements will include both essential and toxic elements in the panel.
Fully Automated Barcode Tracking and Analysis USP Application - plasmaTRAX
Using 2D barcodes, the plasmaTRAX™ system fully automates the USP <232> <233> protocols. Sample information is permanently associated with TRAXID barcodes and can be communicated to LIMS for complete sample tracking and report generation.
Fully Automated Inline Sample Introduction System for Total Metals and Elemental Speciation in Clinical Samples - prepFAST IC
This work demonstrates the use of the prepFAST IC as the front-end sample introduction system for analyzing undiluted blood, serum, plasma, and urine. The undiluted biological samples are loaded by vacuum or syringe, depending on the matrix and the amount of sample available.
Goldschmidt Paris 2017 Poster Note -Measurement of Stable Isotope 41K/39K Ratios by MC-ICP-MS - apex Omega
The measurement of the stable isotope ratio 41K/39K by conventional MC-ICP-MS is challenging due to scattered ions from 40Ar+ and interference by 40Ar1 H+. TIMS and SIMS are not sufficiently precise to resolve the small spread of isotopic variation.
hydrideFAST 2 ICP-OES: Environmental - hydrideFAST
The hydrideFAST 2 is an inline sample introduction system that revolutionizes hydride generation by enabling simultaneous determination of both hydride and nebulized elements. The system enhances sensitivity for hydride-forming elements while maintaining the multi-element capabilities of direct nebulization.
prepFAST MC Environmental: Bioavailable Trace Metals - prepFAST MC
The prepFAST MC is a fully automated low pressure chromatography system that can isolate and collect discrete fractions from a dissolved sample. The syringe driven system allows sample loading, elution and column conditioning cycles all with user-defined parameters (time, volume and flow rate).
prepFAST CMP : Inline Chemistry for High Silicon Applications - prepFAST CMP
The prepFAST CMP system preconcentrates trace elemental impurities from high silicon matrices for exceptional interference removal and excellent detection limits for many critical metals in CMP slurries.
prepFAST IC: Inline Autodilution Method to Eliminate Species Interconversion for LC-ICPMS Based Applications - prepFAST IC
The following study will be focused on arsenic species in urine in order to demonstrate the capabilities of the prepFAST IC. This study will look at the precision and robustness for a syringe driven LC method, the advantages of autocalibration and autodilution of samples versus manual preparation, and figures of merit.
prepFAST IC: Inline Autodilution Method to Measure Hexavalent Chromium in Drinking Water - prepFAST IC
The amount of chromium in drinking water has been a controversial and debatable topic recently. The EPA set the federal drinking water maximum contaminant level (MCL) to be less than 100 ppb total Cr based on a study from 1991.

1